STAT3(Signal Transducer and Activator of Transcription 3) ELISA Kit (UNES00063)
- SKU:
- UNES00063
- Product Type:
- ELISA Kit
- Size:
- 96 Assays
- Uniprot:
- P40763
- Sensitivity:
- 0.19ng/mL
- Range:
- 0.31-20ng/mL
- ELISA Type:
- Sandwich
- Reactivity:
- Universal
- Sample Type:
- Serum, plasma and other biological fluids
Description
STAT3 (Signal Transducer and Activator of Transcription 3) ELISA Kit (UNES00063)
The STAT3 (Signal Transducer and Activator of Transcription 3) ELISA Kit is a highly sensitive and specific assay designed for the accurate detection of STAT3 levels in various biological samples, including serum, plasma, and cell culture supernatants. This kit provides reliable and reproducible results, making it ideal for a wide range of research applications.STAT3 is a key transcription factor that plays a critical role in cell growth, differentiation, and survival. Abnormal STAT3 signaling has been associated with various diseases, including cancer, inflammatory disorders, and autoimmune diseases.
The STAT3 ELISA Kit enables researchers to quantify STAT3 levels, providing valuable insights into the molecular mechanisms underlying these diseases and potential therapeutic targets.Overall, the STAT3 ELISA Kit offers researchers a powerful tool for studying STAT3 signaling pathways and developing novel treatments for diseases associated with dysregulated STAT3 activity.
Assay type: | Sandwich |
Format: | 96T |
Assay time: | 4.5h |
Reactivity: | Universal |
Detection Method: | Colormetric |
Detection Range: | 0.31-20 ng/mL |
Sensitivity: | 0.19 ng/mL |
Sample Volume Required Per Well: | 100µL |
Sample Type: | Serum, plasma and other biological fluids |
Specificity: | This kit recognizes STAT3 in samples. No significant cross-reactivity or interference between STAT3 and analogues was observed. |
This ELISA kit uses Competitive-ELISA as the method. The microtiter plate provided in this kit has been pre-coated with STAT3. During the reaction, STAT3 in the sample or standard competes with a fixed amount of STAT3 on the solid phase supporter for sites on the Biotinylated Detection Ab specific to STAT3. Excess conjugate and unbound sample or standard are washed from the plate, and Avidin conjugated to Horseradish Peroxidase (HRP) are added to each microplate well and incubated. Then a TMB substrate solution is added to each well. The enzyme-substrate reaction is terminated by adding Stop Solution and the color change is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The concentration of STAT3 in the samples is then determined by comparing the OD of the samples to the standard curve.
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e. g. operator, pipetting technique, washing technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data is provided below for reference only.
Concentration (ng/mL) | O.D | Average | Corrected |
20 | 2.31 2.314 | 2.312 | 2.242 |
10 | 1.461 1.475 | 1.468 | 1.398 |
5 | 0.824 0.82 | 0.822 | 0.752 |
2.5 | 0.443 0.463 | 0.453 | 0.383 |
1.25 | 0.223 0.217 | 0.22 | 0.15 |
0.63 | 0.176 0.146 | 0.161 | 0.091 |
0.31 | 0.113 0.121 | 0.117 | 0.047 |
0 | 0.064 0.076 | 0.07 | -- |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level STAT3 were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level STAT3 were tested on 3 different plates, 20 replicates in each plate.
Intra-assay Precision | Inter-assay Precision | |||||
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 20 | 20 | 20 | 20 | 20 | 20 |
Mean (ng/mL) | 1.01 | 2.83 | 8.61 | 1.01 | 2.73 | 8.25 |
Standard deviation | 0.06 | 0.15 | 0.28 | 0.07 | 0.12 | 0.37 |
C V (%) | 5.94 | 5.30 | 3.25 | 6.93 | 4.40 | 4.48 |
Recovery
The recovery of STAT3 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type | Range (%) | Average Recovery (%) |
Serum (n=5) | 89-99 | 94 |
EDTA plasma (n=5) | 88-103 | 96 |
Cell culture media (n=5) | 84-99 | 91 |
Linearity
Samples were spiked with high concentrations of STAT3 and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.
Serum (n=5) | EDTA plasma (n=5) | Cell culture media (n=5) | ||
1:2 | Range (%) | 86-97 | 98-113 | 92-108 |
Average (%) | 92 | 105 | 99 | |
1:4 | Range (%) | 89-102 | 88-100 | 83-98 |
Average (%) | 96 | 93 | 89 | |
1:8 | Range (%) | 91-103 | 82-91 | 85-96 |
Average (%) | 98 | 86 | 90 | |
1:16 | Range (%) | 90-104 | 85-95 | 84-96 |
Average (%) | 98 | 90 | 90 |
An unopened kit can be stored at 4°C for 1 month. If the kit is not used within 1 month, store the items separately according to the following conditions once the kit is received.
Item | Specifications | Storage |
Micro ELISA Plate(Dismountable) | 8 wells ×12 strips | -20°C, 6 months |
Reference Standard | 2 vials | |
Concentrated Biotinylated Detection Ab (100×) | 1 vial, 120 µL | |
Concentrated HRP Conjugate (100×) | 1 vial, 120 µL | -20°C (shading light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 4°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | |
HRP Conjugate Diluent | 1 vial, 14 mL | |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | |
Substrate Reagent | 1 vial, 10 mL | 4°C (shading light) |
Stop Solution | 1 vial, 10 mL | 4°C |
Plate Sealer | 5 pieces | |
Product Description | 1 copy | |
Certificate of Analysis | 1 copy |
- Set standard, test sample and control (zero) wells on the pre-coated plate and record theirpositions. It is recommended to measure each standard and sample in duplicate. Note: addall solutions to the bottom of the plate wells while avoiding contact with the well walls. Ensuresolutions do not foam when adding to the wells.
- Aliquot 100µl of standard solutions into the standard wells.
- Add 100µl of Sample / Standard dilution buffer into the control (zero) well.
- Add 100µl of properly diluted sample (serum, plasma, tissue homogenates and otherbiological fluids) into test sample wells.
- Cover the plate with the sealer provided in the kit and incubate for 90 min at 37°C.
- Aspirate the liquid from each well, do not wash. Immediately add 100µL of BiotinylatedDetection Ab working solution to each well. Cover the plate with a plate seal and gently mix. Incubate for 1 hour at 37°C.
- Aspirate or decant the solution from the plate and add 350µL of wash buffer to each welland incubate for 1-2 minutes at room temperature. Aspirate the solution from each well andclap the plate on absorbent filter paper to dry. Repeat this process 3 times. Note: a microplatewasher can be used in this step and other wash steps.
- Add 100µL of HRP Conjugate working solution to each well. Cover with a plate seal andincubate for 30 min at 37°C.
- Aspirate or decant the solution from each well. Repeat the wash process for five times asconducted in step 7.
- Add 90µL of Substrate Reagent to each well. Cover with a new plate seal and incubate forapproximately 15 min at 37°C. Protect the plate from light. Note: the reaction time can beshortened or extended according to the actual color change, but not by more than 30min.
- Add 50 µL of Stop Solution to each well. Note: Adding the stop solution should be done inthe same order as the substrate solution.
- Determine the optical density (OD value) of each well immediately with a microplate readerset at 450 nm.