Rat Heat Shock Protein 90kDa Alpha B1 (HSP90aB1) ELISA Kit
The Rat Heat Shock Protein 90kDa Alpha B1 (HSP90AB1) ELISA Kit is a powerful tool for researchers seeking to accurately measure levels of this important protein in rat samples. This kit offers high sensitivity and specificity, ensuring precise and consistent results in serum, plasma, and cell culture supernatants.HSP90AB1 is a key component of the heat shock protein family, playing a critical role in cellular stress response and protein folding. Dysregulation of HSP90AB1 has been linked to various diseases, including cancer, neurodegenerative disorders, and cardiovascular diseases.
By studying levels of HSP90AB1, researchers can gain valuable insights into disease mechanisms and potentially identify new therapeutic targets.With its reliable performance and broad applicability, the Rat HSP90AB1 ELISA Kit is an essential tool for studies involving heat shock proteins and their role in health and disease.
Product Name:
Rat Heat Shock Protein 90kDa Alpha B1 (HSP90aB1) ELISA Kit
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-101
91
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.