Rat G1/S-specific cyclin-D1 (Ccnd1) ELISA Kit
- SKU:
- RTEB0356
- Product Type:
- ELISA Kit
- Size:
- 96 Assays
- Uniprot:
- P39948
- Range:
- 0.312-20 ng/mL
- ELISA Type:
- Sandwich
- Synonyms:
- Ccnd1, BCL-1, PRAD1 oncogene, B-cell lymphoma 1 protein, BCL-1 oncogene, BCL1, PRAD1, Cyclin-D1, Cyl-1, cyclin D1, G1, S-specific cyclin D1, G1, S-specific cyclin-D1, PRAD1B-cell CLL, lymphoma 1
- Reactivity:
- Rat
Description
Product Name: | Rat G1/S-specific cyclin-D1 (Ccnd1) ELISA Kit |
Product Code: | RTEB0356 |
Alias: | G1/S-specific cyclin-D1, Ccnd1 |
Uniprot: | P39948 |
Reactivity: | Rat |
Range: | 0.312-20 ng/mL |
Detection Method: | Sandwich |
Size: | 96 Assay |
Storage: | Please see kit components below for exact storage details |
Note: | For research use only |
UniProt Protein Function: | CCND1: a member of the highly conserved cyclin family, whose members are characterized by a dramatic periodicity in protein abundance through the cell cycle. Cyclins function as regulators of CDK kinases. Forms a complex with and functions as a regulatory subunit of CDK4 or CDK6, whose activity is required for cell cycle G1/S transition. This protein has been shown to interact with tumor suppressor protein Rb and the expression of this gene is regulated positively by Rb. |
UniProt Protein Details: | Protein type:Oncoprotein; Activator; Cell cycle regulation; Nuclear receptor co-regulator Cellular Component: nucleoplasm; tight junction; transcriptional repressor complex; membrane; cytoplasm; cyclin-dependent protein kinase holoenzyme complex; intracellular; nucleus Molecular Function:enzyme binding; histone deacetylase binding; protein complex binding; kinase activity; cyclin-dependent protein kinase regulator activity; transcription corepressor activity; transcription factor binding; protein kinase binding; protein kinase activity Biological Process: G1 DNA damage checkpoint; lactation; fat cell differentiation; re-entry into mitotic cell cycle; negative regulation of Wnt receptor signaling pathway; positive regulation of cyclin-dependent protein kinase activity; regulation of cell cycle; response to glucocorticoid stimulus; positive regulation of mammary gland epithelial cell proliferation; negative regulation of epithelial cell differentiation; Wnt receptor signaling pathway through beta-catenin; negative regulation of transcription from RNA polymerase II promoter; response to organic cyclic substance; protein amino acid phosphorylation; response to estradiol stimulus; response to organic substance; response to magnesium ion; response to vitamin E; Leydig cell differentiation; positive regulation of cell proliferation; response to iron ion; response to corticosterone stimulus; response to X-ray; response to drug; organ regeneration; Wnt receptor signaling pathway; transcription, DNA-dependent; unfolded protein response; mammary gland epithelial cell proliferation; liver development; response to organic nitrogen; response to ethanol; cell division; response to steroid hormone stimulus; response to estrogen stimulus; positive regulation of protein amino acid phosphorylation; response to calcium ion; regulation of protein kinase activity; response to DNA damage stimulus; G1/S transition of mitotic cell cycle |
NCBI Summary: | regulatory subunit of CDK4 or CDK6; involved in regulation of the G1/S transition of the cell cycle [RGD, Feb 2006] |
UniProt Code: | P39948 |
NCBI GenInfo Identifier: | 148356229 |
NCBI Gene ID: | 58919 |
NCBI Accession: | NP_741989.3 |
UniProt Related Accession: | P39948 |
Molecular Weight: | Predicted Molecular Mass: 34.7kDaAccurate Molecular Mass: 34kDa as determined by SDS-PAGE reducing conditions. |
NCBI Full Name: | G1/S-specific cyclin-D1 |
NCBI Synonym Full Names: | cyclin D1 |
NCBI Official Symbol: | Ccnd1 |
NCBI Protein Information: | G1/S-specific cyclin-D1 |
UniProt Protein Name: | G1/S-specific cyclin-D1 |
Protein Family: | G1/S-specific cyclin |
UniProt Gene Name: | Ccnd1 |
UniProt Entry Name: | CCND1_RAT |
Component | Quantity (96 Assays) | Storage |
ELISA Microplate (Dismountable) | 8×12 strips | -20°C |
Lyophilized Standard | 2 | -20°C |
Sample Diluent | 20ml | -20°C |
Assay Diluent A | 10mL | -20°C |
Assay Diluent B | 10mL | -20°C |
Detection Reagent A | 120µL | -20°C |
Detection Reagent B | 120µL | -20°C |
Wash Buffer | 30mL | 4°C |
Substrate | 10mL | 4°C |
Stop Solution | 10mL | 4°C |
Plate Sealer | 5 | - |
Other materials and equipment required:
- Microplate reader with 450 nm wavelength filter
- Multichannel Pipette, Pipette, microcentrifuge tubes and disposable pipette tips
- Incubator
- Deionized or distilled water
- Absorbent paper
- Buffer resevoir
*Note: The below protocol is a sample protocol. Protocols are specific to each batch/lot. For the correct instructions please follow the protocol included in your kit.
Allow all reagents to reach room temperature (Please do not dissolve the reagents at 37°C directly). All the reagents should be mixed thoroughly by gently swirling before pipetting. Avoid foaming. Keep appropriate numbers of strips for 1 experiment and remove extra strips from microtiter plate. Removed strips should be resealed and stored at -20°C until the kits expiry date. Prepare all reagents, working standards and samples as directed in the previous sections. Please predict the concentration before assaying. If values for these are not within the range of the standard curve, users must determine the optimal sample dilutions for their experiments. We recommend running all samples in duplicate.
Step | |
1. | Add Sample: Add 100µL of Standard, Blank, or Sample per well. The blank well is added with Sample diluent. Solutions are added to the bottom of micro ELISA plate well, avoid inside wall touching and foaming as possible. Mix it gently. Cover the plate with sealer we provided. Incubate for 120 minutes at 37°C. |
2. | Remove the liquid from each well, don't wash. Add 100µL of Detection Reagent A working solution to each well. Cover with the Plate sealer. Gently tap the plate to ensure thorough mixing. Incubate for 1 hour at 37°C. Note: if Detection Reagent A appears cloudy warm to room temperature until solution is uniform. |
3. | Aspirate each well and wash, repeating the process three times. Wash by filling each well with Wash Buffer (approximately 400µL) (a squirt bottle, multi-channel pipette,manifold dispenser or automated washer are needed). Complete removal of liquid at each step is essential. After the last wash, completely remove remaining Wash Buffer by aspirating or decanting. Invert the plate and pat it against thick clean absorbent paper. |
4. | Add 100µL of Detection Reagent B working solution to each well. Cover with the Plate sealer. Incubate for 60 minutes at 37°C. |
5. | Repeat the wash process for five times as conducted in step 3. |
6. | Add 90µL of Substrate Solution to each well. Cover with a new Plate sealer and incubate for 10-20 minutes at 37°C. Protect the plate from light. The reaction time can be shortened or extended according to the actual color change, but this should not exceed more than 30 minutes. When apparent gradient appears in standard wells, user should terminatethe reaction. |
7. | Add 50µL of Stop Solution to each well. If color change does not appear uniform, gently tap the plate to ensure thorough mixing. |
8. | Determine the optical density (OD value) of each well at once, using a micro-plate reader set to 450 nm. User should open the micro-plate reader in advance, preheat the instrument, and set the testing parameters. |
9. | After experiment, store all reagents according to the specified storage temperature respectively until their expiry. |
When carrying out an ELISA assay it is important to prepare your samples in order to achieve the best possible results. Below we have a list of procedures for the preparation of samples for different sample types.
Sample Type | Protocol |
Serum | If using serum separator tubes, allow samples to clot for 30 minutes at room temperature. Centrifuge for 10 minutes at 1,000x g. Collect the serum fraction and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. If serum separator tubes are not being used, allow samples to clot overnight at 2-8°C. Centrifuge for 10 minutes at 1,000x g. Remove serum and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. |
Plasma | Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples at 4°C for 15 mins at 1000 × g within 30 mins of collection. Collect the plasma fraction and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. Note: Over haemolysed samples are not suitable for use with this kit. |
Urine & Cerebrospinal Fluid | Collect the urine (mid-stream) in a sterile container, centrifuge for 20 mins at 2000-3000 rpm. Remove supernatant and assay immediately. If any precipitation is detected, repeat the centrifugation step. A similar protocol can be used for cerebrospinal fluid. |
Cell culture supernatant | Collect the cell culture media by pipette, followed by centrifugation at 4°C for 20 mins at 1500 rpm. Collect the clear supernatant and assay immediately. |
Cell lysates | Solubilize cells in lysis buffer and allow to sit on ice for 30 minutes. Centrifuge tubes at 14,000 x g for 5 minutes to remove insoluble material. Aliquot the supernatant into a new tube and discard the remaining whole cell extract. Quantify total protein concentration using a total protein assay. Assay immediately or aliquot and store at ≤ -20 °C. |
Tissue homogenates | The preparation of tissue homogenates will vary depending upon tissue type. Rinse tissue with 1X PBS to remove excess blood & homogenize in 20ml of 1X PBS (including protease inhibitors) and store overnight at ≤ -20°C. Two freeze-thaw cycles are required to break the cell membranes. To further disrupt the cell membranes you can sonicate the samples. Centrifuge homogenates for 5 mins at 5000xg. Remove the supernatant and assay immediately or aliquot and store at -20°C or -80°C. |
Tissue lysates | Rinse tissue with PBS, cut into 1-2 mm pieces, and homogenize with a tissue homogenizer in PBS. Add an equal volume of RIPA buffer containing protease inhibitors and lyse tissues at room temperature for 30 minutes with gentle agitation. Centrifuge to remove debris. Quantify total protein concentration using a total protein assay. Assay immediately or aliquot and store at ≤ -20 °C. |
Breast Milk | Collect milk samples and centrifuge at 10,000 x g for 60 min at 4°C. Aliquot the supernatant and assay. For long term use, store samples at -80°C. Minimize freeze/thaw cycles. |