The Rat Coupling Factor 6 (CF6) ELISA Kit is a specialized assay designed for the precise measurement of CF6 levels in rat biological samples such as serum, plasma, and tissue lysates. With its exceptional sensitivity and specificity, this kit delivers accurate and consistent results, making it an invaluable tool for various research applications.CF6 is an important factor in cellular signaling pathways, particularly in the regulation of cell growth and differentiation. Its role in various physiological processes makes it a key target for studying diseases such as cancer, metabolic disorders, and immune-related conditions.
By accurately quantifying CF6 levels, researchers can gain insights into the mechanisms underlying these diseases and potentially identify new therapeutic approaches.Overall, the Rat Coupling Factor 6 (CF6) ELISA Kit offers researchers a dependable and efficient method for investigating the role of CF6 in biological processes and disease pathogenesis. Its high-quality performance and ease of use make it a valuable addition to any laboratory studying rat models and related diseases.
Product Name:
Rat Coupling Factor 6 (CF6) ELISA Kit
Product Code:
RTDL00201
Size:
96 Assays
Target:
CF6
Synonyms:
ATP5J, ATP5A, ATP5, ATPM, ATP Synthase,H+ Transporting,Mitochondrial Fo Complex,Subunit F6, ATP synthase-coupling factor 6, mitochondrial
Detection Method:
Sandwich
Range:
0.781-50ng/mL
Shelf Life:
12 months
Note:
For research use only
Recovery:
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-99
90
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.