GBP28,ApM1,AdipoQ,Acrp30,ACDC,APM1,C1Q And Collagen Domain Containing,Adipocyte Complement-Related Protein Of 30 KDa,Adipose Most Abundant Gene Transcript 1
The Rabbit Adiponectin (ADP) ELISA Kit is specifically designed for the precise measurement of adiponectin levels in rabbit serum, plasma, and cell culture supernatants. This cutting-edge kit offers exceptional sensitivity and specificity, guaranteeing consistent and dependable results for various research purposes.Adiponectin is a vital protein known for its role in regulating glucose levels, fatty acid breakdown, and inflammation within the body.
Abnormal adiponectin levels have been linked to obesity, insulin resistance, and cardiovascular diseases, making it a valuable biomarker for studying these conditions and exploring potential treatment options.With the Rabbit Adiponectin ELISA Kit, researchers can accurately assess adiponectin levels in rabbit samples, helping to advance our understanding of metabolic disorders and develop targeted therapies to improve human health.
Product Name:
Rabbit Adiponectin (ADP) ELISA Kit
Product Code:
RBDL00002
Size:
96 Assays
Target:
ADP
Synonyms:
GBP28, ApM1, AdipoQ, Acrp30, ACDC, APM1, C1Q And Collagen Domain Containing, Adipocyte Complement-Related Protein Of 30 KDa, Adipose Most Abundant Gene Transcript 1
Detection Method:
Sandwich
Range:
0.312-20ng/mL
Shelf Life:
12 months
Note:
For research use only
Recovery:
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-99
90
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.