The Mouse Heat Shock Protein 40 (HSP40) ELISA Kit is a reliable and accurate tool for the detection of HSP40 levels in mouse serum, plasma, and cell culture supernatants. With its high sensitivity and specificity, this kit ensures precise and reproducible results, making it perfect for a variety of research applications.HSP40 is an important protein involved in the heat shock response, playing a crucial role in protein folding and cellular stress response.
It is essential for maintaining cellular homeostasis and protecting cells from damage caused by stressors such as high temperatures.This ELISA kit is essential for studying the function of HSP40 in various biological processes, including aging, cancer, and neurodegenerative diseases. It is a valuable tool for researchers looking to understand the mechanisms of protein folding and stress response in the context of different diseases and conditions.
Product Name:
Mouse Heat Shock Protein 40 (HSP40) ELISA Kit
Product Code:
MODL00637
Size:
96 Assays
Target:
HSP40
Synonyms:
DnaJ, DNAJB1, Sis1, RSPH16B, HSPF1, DnaJ homolog subfamily B member 1, Radial Spoke 16 Homolog B, Heat Shock 40kDa Protein 1, DnaJ protein homolog 1
Detection Method:
Sandwich
Range:
0.625-40ng/mL
Shelf Life:
12 months
Note:
For research use only
Recovery:
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
83-100
91
EDTA plasma (n=5)
91-98
94
Heparin plasma (n=5)
90-99
94
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.