The Mouse Cytochrome P450 27B1 (CYP27B1) ELISA Kit is specifically designed for the accurate detection of CYP27B1 levels in mouse serum, plasma, and cell culture supernatants. This kit offers high sensitivity and specificity for reliable and reproducible results, making it an essential tool for researchers in the field.CYP27B1 is an important enzyme involved in the metabolism of vitamin D, playing a crucial role in calcium homeostasis and bone health. Dysregulation of CYP27B1 activity has been implicated in various diseases, including renal disorders, metabolic disorders, and autoimmune conditions.
Therefore, measuring CYP27B1 levels can provide valuable insights into these physiological processes and disease states.With its easy-to-use format and superior performance, the Mouse CYP27B1 ELISA Kit from AssayGenie is a valuable resource for studying vitamin D metabolism and its impact on health and disease in mouse models.
Product Name:
Mouse Cytochrome P450 27B1 (CYP27B1) ELISA Kit
Product Code:
MODL00342
Size:
96 Assays
Target:
CYP27B1
Synonyms:
VDD1, PDDR, CYP1, P450c1, 25-Hydroxyvitamin D3 1-Alpha-Hydroxylase, Cytochrome P450 Family 27 Subfamily B Polypeptide 1, Calcidiol 1-monooxygenase, VD3 1A hydroxylase
Detection Method:
Sandwich
Range:
0.625-40ng/mL
Shelf Life:
12 months
Note:
For research use only
Recovery:
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-101
91
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.