The Mouse Cofilin-1 (Non-muscle) CFL1 ELISA Kit is specially designed for the accurate detection of non-muscle cofilin-1 levels in mouse serum, plasma, and cell culture supernatants. This ELISA kit offers high sensitivity and specificity, ensuring reliable and reproducible results for a variety of research applications.Cofilin-1 is a critical protein involved in actin dynamics and cytoskeletal reorganization, playing a crucial role in processes such as cell migration, cell division, and synaptic plasticity.
Dysregulation of cofilin-1 has been linked to various diseases, including cancer, neurodegenerative disorders, and autoimmune diseases, making it an important biomarker for understanding these conditions and exploring potential therapeutic interventions.Overall, the Mouse Cofilin-1 (Non-muscle) CFL1 ELISA Kit provides researchers with a powerful tool to study the role of cofilin-1 in various biological processes and diseases, offering valuable insights for future research and drug development efforts.
Product Name:
Mouse Cofilin 1, Non Muscle (CFL1) ELISA Kit
Product Code:
MODL00256
Size:
96 Assays
Target:
CFL1
Synonyms:
CFL, p18, N-Cofilin, 18 kDa phosphoprotein
Detection Method:
Sandwich
Range:
0.312-20ng/mL
Shelf Life:
12 months
Note:
For research use only
Recovery:
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-100
90
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.