Mouse Autophagy Related Protein 7 (ATG7) ELISA Kit
The Mouse ATG7 (Autophagy-related Protein 7) ELISA Kit is specifically designed for the quantitative detection of ATG7 levels in mouse serum, plasma, and tissue lysates. This kit offers exceptional sensitivity and accuracy, ensuring precise and consistent results for a variety of research purposes.ATG7 is a key protein involved in the autophagy process, which is essential for maintaining cellular homeostasis and removing damaged organelles.
Dysregulation of autophagy has been linked to various diseases, including cancer, neurodegenerative disorders, and metabolic conditions, highlighting the importance of studying ATG7 levels.With its reliability and performance, the Mouse ATG7 ELISA Kit is an invaluable tool for researchers investigating autophagy and its role in disease pathology, as well as for developing potential therapeutic interventions.
Product Name:
Mouse Autophagy Related Protein 7 (ATG7) ELISA Kit
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-100
90
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.