The Human Integrin-Associated Protein (IAP) ELISA Kit is specifically designed for the precise detection of integrin-associated protein levels in human samples such as serum, plasma, and cell culture supernatants. This ELISA kit offers exceptional sensitivity and specificity, ensuring accurate and reproducible results for a variety of research applications.Integrin-associated protein, also known as CD47, plays a vital role in cell adhesion and signal transduction processes. It is involved in various physiological and pathological processes, including immune response, tumor progression, and cardiovascular diseases.
The measurement of integrin-associated protein levels can provide valuable insight into these conditions and aid in the development of potential therapeutic strategies.With its high reliability and performance, the Human Integrin-Associated Protein (IAP) ELISA Kit is an essential tool for researchers studying the role of integrin-associated protein in health and disease. Get your kit today and unlock the potential of your research!
Product Name:
Human Integrin Associated Protein (IAP) ELISA Kit
Product Code:
HUDL01415
Size:
96 Assays
Target:
IAP
Synonyms:
CD47, MER6, OA3, Antigen Identified By Monoclonal Antibody 1D8, Antigenic Surface Determinant Protein OA3, Rh-Related Antigen
Detection Method:
Sandwich
Range:
0.312-20ng/mL
Shelf Life:
12 months
Note:
For research use only
Recovery:
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-99
90
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.