The Human CLOCK (Circadian Locomotor Output Cycles Kaput) ELISA Kit is a powerful tool for accurately measuring CLOCK levels in human biological samples. This kit offers outstanding sensitivity and specificity, guaranteeing precise and consistent results for a variety of research purposes.CLOCK is a key protein involved in regulating circadian rhythms, controlling the body's internal clock and influencing various physiological processes.
Dysregulation of CLOCK has been linked to various health conditions, including sleep disorders, metabolic disorders, and mood disorders, making it a valuable biomarker for studying these diseases and exploring potential treatment options.With its ease of use and reliable performance, the Human CLOCK ELISA Kit is an essential tool for researchers investigating circadian biology and its implications for human health.
Product Name:
Human Clock Homolog (CLOCK) ELISA Kit
Product Code:
HUDL00599
Size:
96 Assays
Target:
CLOCK
Synonyms:
KAT13D, bHLHe8, Class E basic helix-loop-helix protein 8, Circadian Locomoter Output Cycles Protein Kaput
Detection Method:
Sandwich
Range:
0.312-20ng/mL
Shelf Life:
12 months
Note:
For research use only
Recovery:
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-100
90
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.