Human BMP-3 (Bone Morphogenetic Protein 3) ELISA Kit (HUES01517)
- SKU:
- HUES01517
- Product Type:
- ELISA Kit
- Size:
- 96 Assays
- Uniprot:
- P12645
- Sensitivity:
- 0.09ng/mL
- Range:
- 0.16-10ng/mL
- ELISA Type:
- Sandwich
- Synonyms:
- BMP3, BMP3A, BMP-3A
- Reactivity:
- Human
- Sample Type:
- Serum, plasma and other biological fluids
- Research Area:
- Cell Biology
Description
Human BMP-3 (Bone Morphogenetic Protein 3) ELISA Kit
The Human BMP-3 (Bone Morphogenetic Protein 3) ELISA Kit from Assay Genie is a cutting-edge tool for the precise measurement of BMP-3 levels in human samples such as serum, plasma, and cell culture supernatants. This kit offers exceptional sensitivity and specificity, ensuring accurate and reproducible results for a variety of research applications.BMP-3 is a vital protein involved in bone development and regeneration, as well as other cellular processes such as differentiation and proliferation. Abnormal BMP-3 levels have been associated with various diseases and disorders, making it a valuable biomarker for studying conditions like osteoporosis, skeletal disorders, and certain cancers.
By accurately measuring BMP-3 levels, researchers can gain valuable insights into these conditions and potentially develop new treatment strategies.Overall, the Human BMP-3 ELISA Kit from Assay Genie is an indispensable tool for researchers studying bone metabolism, tissue regeneration, and related diseases. Its reliability and precision make it an essential addition to any laboratory conducting cutting-edge research in these areas.
Assay type: | Sandwich |
Format: | 96T |
Assay time: | 4.5h |
Reactivity: | Human |
Detection Method: | Colormetric |
Detection Range: | 0.16-10 ng/mL |
Sensitivity: | 0.10 ng/mL |
Sample Volume Required Per Well: | 100µL |
Sample Type: | Serum, plasma and other biological fluids |
Specificity: | This kit recognizes Human BMP-3 in samples. No significant cross-reactivity or interference between Human BMP-3 and analogues was observed. |
This ELISA kit uses Sandwich-ELISA as the method. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Human BMP-3. Standards or samples are added to the appropriate micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human BMP-3 and Avidin-Horseradish Peroxidase (HRP) conjugate are added to each micro plate well successively and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human BMP-3, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by adding Stop Solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of Human BMP-3. The concentration of Human BMP-3 in samples can be calculated by comparing the OD of the samples to the standard curve.
UniProt Protein Function: | BMP3: Negatively regulates bone density. Antagonizes the ability of certain osteogenic BMPs to induce osteoprogenitor differentitation and ossification. Belongs to the TGF-beta family. |
UniProt Protein Details: | Protein type:Secreted; Secreted, signal peptide; Cytokine Chromosomal Location of Human Ortholog: 4q21 Cellular Component: extracellular space Molecular Function:cytokine activity; receptor binding; transforming growth factor beta receptor binding Biological Process: BMP signaling pathway; cell development; cell-cell signaling; regulation of apoptosis; regulation of MAPKKK cascade; skeletal development |
NCBI Summary: | BMP3 belongs to the transforming growth factor-beta (TGFB) superfamily. Bone morphogenic protein, also known as osteogenin, induces bone formation. [provided by RefSeq, Jul 2008] |
UniProt Code: | P12645 |
NCBI GenInfo Identifier: | 215273985 |
NCBI Gene ID: | 651 |
NCBI Accession: | P12645. 2 |
UniProt Secondary Accession: | P12645,Q4VAS5, |
UniProt Related Accession: | P12645 |
Molecular Weight: | 53,372 Da |
NCBI Full Name: | Bone morphogenetic protein 3 |
NCBI Synonym Full Names: | bone morphogenetic protein 3 |
NCBI Official Symbol: | BMP3 |
NCBI Official Synonym Symbols: | BMP-3A |
NCBI Protein Information: | bone morphogenetic protein 3 |
UniProt Protein Name: | Bone morphogenetic protein 3 |
UniProt Synonym Protein Names: | Bone morphogenetic protein 3A; BMP-3A; Osteogenin |
Protein Family: | Bone morphogenetic protein |
UniProt Gene Name: | BMP3 |
UniProt Entry Name: | BMP3_HUMAN |
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e. g. operator, pipetting technique, washing technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data is provided below for reference only.
Concentration (ng/mL) | O.D | Average | Corrected |
10 | 2.458 2.504 | 2.481 | 2.396 |
5 | 1.672 1.728 | 1.7 | 1.615 |
2.5 | 0.916 0.884 | 0.9 | 0.815 |
1.25 | 0.482 0.488 | 0.485 | 0.4 |
0.63 | 0.286 0.262 | 0.274 | 0.189 |
0.32 | 0.202 0.172 | 0.187 | 0.102 |
0.16 | 0.134 0.14 | 0.137 | 0.052 |
0 | 0.075 0.095 | 0.085 | -- |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level Human BMP-3 were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level Human BMP-3 were tested on 3 different plates, 20 replicates in each plate.
Intra-assay Precision | Inter-assay Precision | |||||
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 20 | 20 | 20 | 20 | 20 | 20 |
Mean (ng/mL) | 0.54 | 1.36 | 4.30 | 0.54 | 1.23 | 4.11 |
Standard deviation | 0.03 | 0.05 | 0.18 | 0.04 | 0.07 | 0.21 |
C V (%) | 5.56 | 3.68 | 4.19 | 7.41 | 5.69 | 5.11 |
Recovery
The recovery of Human BMP-3 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type | Range (%) | Average Recovery (%) |
Serum (n=5) | 90-100 | 95 |
EDTA plasma (n=5) | 92-108 | 100 |
Cell culture media (n=5) | 89-100 | 95 |
Linearity
Samples were spiked with high concentrations of Human BMP-3 and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.
Serum (n=5) | EDTA plasma (n=5) | Cell culture media (n=5) | ||
1:2 | Range (%) | 89-104 | 91-105 | 91-106 |
Average (%) | 96 | 98 | 98 | |
1:4 | Range (%) | 90-102 | 81-93 | 84-95 |
Average (%) | 95 | 86 | 89 | |
1:8 | Range (%) | 93-108 | 83-93 | 86-96 |
Average (%) | 100 | 88 | 91 | |
1:16 | Range (%) | 86-98 | 86-101 | 87-99 |
Average (%) | 92 | 92 | 93 |
An unopened kit can be stored at 4°C for 1 month. If the kit is not used within 1 month, store the items separately according to the following conditions once the kit is received.
Item | Specifications | Storage |
Micro ELISA Plate(Dismountable) | 8 wells ×12 strips | -20°C, 6 months |
Reference Standard | 2 vials | |
Concentrated Biotinylated Detection Ab (100×) | 1 vial, 120 µL | |
Concentrated HRP Conjugate (100×) | 1 vial, 120 µL | -20°C(shading light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 4°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | |
HRP Conjugate Diluent | 1 vial, 14 mL | |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | |
Substrate Reagent | 1 vial, 10 mL | 4°C(shading light) |
Stop Solution | 1 vial, 10 mL | 4°C |
Plate Sealer | 5 pieces | |
Product Description | 1 copy | |
Certificate of Analysis | 1 copy |
- Set standard, test sample and control (zero) wells on the pre-coated plate and record theirpositions. It is recommended to measure each standard and sample in duplicate. Note: addall solutions to the bottom of the plate wells while avoiding contact with the well walls. Ensuresolutions do not foam when adding to the wells.
- Aliquot 100 µL of standard solutions into the standard wells.
- Add 100 µL of Sample / Standard dilution buffer into the control (zero) well.
- Add 100 µL of properly diluted sample (serum, plasma, tissue homogenates and otherbiological fluids) into test sample wells.
- Cover the plate with the sealer provided in the kit and incubate for 90 min at 37 °C.
- Aspirate the liquid from each well, do not wash. Immediately add 100 µL of BiotinylatedDetection Ab working solution to each well. Cover the plate with a plate seal and gently mix. Incubate for 1 hour at 37 °C.
- Aspirate or decant the solution from the plate and add 350 µL of wash buffer to each welland incubate for 1-2 minutes at room temperature. Aspirate the solution from each well andclap the plate on absorbent filter paper to dry. Repeat this process 3 times. Note: a microplatewasher can be used in this step and other wash steps.
- Add 100 µL of HRP Conjugate working solution to each well. Cover with a plate seal andincubate for 30 min at 37 °C.
- Aspirate or decant the solution from each well. Repeat the wash process for five times asconducted in step 7.
- Add 90 µL of Substrate Reagent to each well. Cover with a new plate seal and incubate forapproximately 15 min at 37 °C. Protect the plate from light. Note: the reaction time can beshortened or extended according to the actual color change, but not by more than 30min.
- Add 50 µL of Stop Solution to each well. Note: Adding the stop solution should be done inthe same order as the substrate solution.
- Determine the optical density (OD value) of each well immediately with a microplate readerset at 450 nm.