Human ATPase, Cu++ Transporting Beta Polypeptide (ATP7b) ELISA Kit
The Human ATPase Cu-Transporting Beta Polypeptide (ATP7B) ELISA Kit is specifically designed for the quantification of ATP7B levels in human serum, plasma, and cell culture supernatants. This high-quality kit offers exceptional sensitivity and specificity, ensuring accurate and reproducible results for various research applications.ATP7B is a crucial protein involved in copper transport within cells, playing a vital role in maintaining copper homeostasis.
Mutations in the ATP7B gene are associated with Wilson's disease, a rare inherited disorder characterized by copper accumulation in the liver and other tissues. The ATP7B ELISA kit serves as a valuable tool for studying the role of ATP7B in copper metabolism-related disorders and developing potential therapies.
Product Name:
Human ATPase, Cu++ Transporting Beta Polypeptide (ATP7b) ELISA Kit
Product Code:
HUDL00291
Size:
96 Assays
Target:
ATP7b
Synonyms:
PWD, WC1, WD, WND, Wilson Disease Protein, Copper pump 2, Wilson disease-associated protein
Detection Method:
Sandwich
Range:
0.156-10ng/mL
Shelf Life:
12 months
Note:
For research use only
Recovery:
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
83-100
91
EDTA plasma (n=5)
91-100
95
Heparin plasma (n=5)
91-101
96
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
3.
Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
4.
Aspirate and wash 3 times
5.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
6.
Aspirate and wash 5 times
7.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
8.
Add 50µL Stop Solution. Read at 450nm immediately.