General Asymmetrical Dimethylarginine (ADMA) ELISA Kit
The General Asymmetrical Dimethylarginine (ADMA) ELISA Kit from Assay Genie is a powerful tool for researchers looking to accurately measure ADMA levels in various biological samples. This kit is optimized for use with human serum, plasma, and cell culture supernatants, offering high sensitivity and specificity for reliable and reproducible results.ADMA is a key player in the regulation of nitric oxide production and has been implicated in a variety of diseases, including cardiovascular disorders, diabetes, and kidney diseases.
By measuring ADMA levels with this ELISA kit, researchers can gain valuable insights into the role of this molecule in disease progression and potentially identify new therapeutic targets.With easy-to-follow protocols and robust performance, the General Asymmetrical Dimethylarginine (ADMA) ELISA Kit is an essential tool for any lab studying the intricate mechanisms of ADMA in health and disease.
Product Name:
General Asymmetrical Dimethylarginine (ADMA) ELISA Kit
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-100
90
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. Note:To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity, and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 50µL standard or sample to each well. And then add 50µL prepared Detection Reagent A immediately. Shake and mix. Incubate 1 hour at 37°C
3.
Aspirate and wash 3 times
4.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
5.
Aspirate and wash 5 times
6.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
7.
Add 50µL Stop Solution. Read at 450 nm immediately.