General 5-Hydroxyindoleacetic Acid (5-HIAA) ELISA Kit
The General 5-Hydroxyindoleacetic Acid (5-HIAA) ELISA Kit is a reliable and accurate tool for detecting levels of 5-HIAA in various biological samples, including serum, plasma, and cell culture supernatants. With its high sensitivity and specificity, this kit ensures precise and reproducible results, making it suitable for a wide range of research applications.5-HIAA is a metabolite of serotonin and is often used as a biomarker for serotonin production and turnover. It plays a crucial role in various physiological processes, including mood regulation, gastrointestinal function, and cardiovascular health.
Abnormal levels of 5-HIAA have been associated with conditions such as carcinoid tumors, depression, and irritable bowel syndrome, making it a valuable target for research and diagnostic purposes.Whether studying neurochemistry, gastrointestinal disorders, or oncology, the General 5-Hydroxyindoleacetic Acid (5-HIAA) ELISA Kit provides a reliable and accurate means of quantifying 5-HIAA levels in biological samples, offering valuable insights into the underlying mechanisms of various diseases and potential therapeutic interventions.
Product Name:
General 5-Hydroxyindoleacetic Acid (5-HIAA) ELISA Kit
Product Code:
UNDL00002
Size:
96 Assays
Target:
5-HIAA
Synonyms:
5HIAA
Detection Method:
Competition
Range:
6.25-400ng/mL
Shelf Life:
12 months
Note:
For research use only
Recovery:
Matrices listed below were spiked with certain level of recombinant the index and the recovery rates were calculated by comparing the measured value to the expected amount of the index in samples.
Matrix
Recovery range (%)
Average(%)
Serum (n=5)
80-102
91
EDTA plasma (n=5)
81-100
90
Heparin plasma (n=5)
80-89
84
Linearity:
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of the index and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample
1:2
1:4
1:8
1:16
Serum (n=5)
82-96%
83-98%
81-99%
93-101%
EDTA plasma (n=5)
88-101%
86-95%
90-102%
80-93%
Heparin plasma (n=5)
80-91%
82-90%
95-104%
79-95%
Intra-assay Precision:
Intra-Assay: CV <10%. 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
Inter-assay Precision:
Inter-Assay: CV <12%. 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
Stability:
The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. Note:To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity, and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
Step
Protocol
1.
Prepare all reagents, samples and standards
2.
Add 50µL standard or sample to each well. And then add 50µL prepared Detection Reagent A immediately. Shake and mix. Incubate 1 hour at 37°C
3.
Aspirate and wash 3 times
4.
Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
5.
Aspirate and wash 5 times
6.
Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
7.
Add 50µL Stop Solution. Read at 450 nm immediately.